Q
To which initial clearance values does the calculation program apply?
A



A: The calculated values apply to normal clearance and larger. Forradial clearance values lower than CN, the radial clearance reduction must bechecked individually depending on the application/operating conditions for, asa rule, there must always be a sufficiently large radial clearance in thebearing.

Previous:Q: When is it necessary to change the pre-set radial clearance reduction?

Next:Q: Is it still necessary to measure the radial clearance?